Reggae From Around The World. Catch the Vibes!
Our LAMBDA 850+ UV/Vis spectrophotometer is one of our highest performance UV/Vis system designed for analysis of coatings, high performance glass, and components in both research and manufacturing. The instrument meets industry standards for ultra-high performance, flexibility, and convenience. false false Part Number L850 Request More Information UV-Visible Lambda 950 Quick Summary For STD Detector 2 For Integrating Sphere mode 175 nm 319.20 nm 860 nm . 3300 nm . D Lamp . Visible region . Tungsten Lamp . NIR region UV region PMT Detector . Slit width Variation Range 0.08 nm-5 nm. PbS Detector (Gain range 1-9, 3 preferred) Slit width Variation Range 0.08 nm-20 nm . Preferred mode Servo i Call 1 (800) 250-6070 ext. 800* to arrange a FREECONSULTATION with a PerkinElmer LAMBDA specialist,or e-mail us: lambda@perkinelmer.com perkinelmer.com/lambda *Phone number is for U.S. and Canada only. For a complete listing of our global offices, visit perkinelmer.com/lasoffices Universal Reflectance Accessory (URA) quality, the PerkinElmer Lambda 800 UV/Vis and Lambda 900 UV/Vis/NIR spectrophotometers are the industry standards for excellence. Perhaps it's because the numerous accessories they have in common make it more cost-effective than ever to own the highest performance spectrophotometers avail-able. With decades of experience, Wavelength Accuracy +/- 0.08 nm UV/Vis +/- 0.08 nm +/- 0.30 nm NIR Wavelength Reproducibility UV/Vis (Deuterium Lamp Lines) ≤ 0.020 nm ≤ 0.020 nm NIR (Deuterium Lamp Lines) ≤ 0.080 nm — Standard deviation of 10 measurements UV/Vis ≤ 0.005 nm ≤ 0.005 nm Standard deviation of 10 measurements NIR ≤ 0.020 nm — Photometric Accuracy Perkin Elmer Lamda1050 UV/Vis/NIR Spectrophotometer. 150 mm integrating sphere with broadband InGaAs detector. Features and specifications: Deuterium and Tungsten Halogen light sources with double grating monochromators. PMT, InGaAs, and PbS 3-detector module for testing across the entire UV/Vis/NIR range from ~200 nm to 3300 nm. Photometric Range LAMBDA 1050 LAMBDA 950 UV/Vis 8 A 8 A NIR 8 A 6 A Photometric Display Unlimited Unlimited Bandpass 0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis range 0.20 nm - 20.00 nm in 0.04 nm increments NIR range Fixed resolution, constant energy or slit programming. 0.05 nm - 5.00 nm in 0.01 nm increments UV/Vis The Cyl 100/PE1050 (with TC 1 Temperature Controller) provides Peltier-based temperature control for a 100 mm pathlength cylindrical cuvette in the Perkin Elmer LAMBDA 650, 750, 850, 950 and 1050 UV/Vis/NIR Spectrophotometers. Place the filled cuvette in a cradle and screw down a cover, thus surrounding the cuvette with temperature-controlled The CD 250/PE1050 for the Perkin Elmer LAMBDA 1050 UV/Vis/NIR Spectrophotometer provides temperature control, dry gas purging and magnetic stirring as needed to a wide range of cuvettes or other samples. This versatility is accomplished using a cuvette carriage which firmly mounts within the temperature controlled tower of the CD 250/PE1050. UV-VIS SPECTROSCOPY. 2 . Lambda 650/850/950 Hardware Guide Release History Part Number Release Publication Date 09300011 A January 2004 Please consult all manuals and CDs supplied with the Lambda 650/850/950 and accessories before you start working with the instrument. Carefully read the safety information in this The LAMBDA 950 is our highest performance UV/Vis/NIR System. C
© 2026 Created by Reggae Nation.
Powered by
You need to be a member of Reggae Nation to add comments!
Join Reggae Nation